Release Notes for inSync Client v6.9.0
Restore data from Shared Data Sources
You can now restore the device data of preserved users if your administrator provides you with the required permission. The shared data sources can be restored from {{insyncweb}} to the configured devices.
Here is a glimpse
Patch update for GovCloud
A patch update v6.9.1 for Windows & macOS is released on September 22, 2021, and contains the fix for the following issue:
Fixed Issue
Issue |
Description |
---|---|
INS-25742 |
Fixed an URL injection vulnerability by adding validation so that no arbitrary URL can be added to load a malicious page. |
Revision Information
Product |
Revision |
---|---|
inSync Client |
Windows: r110192 Mac: r110192 |
To upgrade inSync Client to the latest version, see Upgrade inSync Client.
Download the latest inSync Client here.
To learn more, contact Support.
inSync Client v6.9.1 update for GovCloud
A patch update for v6.9.0 is released on July 24, 2021, and contains the fix for the following issue:
Fixed Issue
Issue | Description |
---|---|
INS-9557 |
Verbose Error Message: version disclosure Fixed an issue related to information disclosure wherein during execution of payload injection in the cookie header field, the application revealed the CherryPy framework version information. |
Revision Information
Product | Revision details |
---|---|
inSync Client |
Windows: r110080 macOS: r110080 Druva has not released a new version of inSync Client for Linux OS with inSync Client v6.9.1. You can continue using inSync Client v5.9 for Linux with inSync GovCloud. |
inSync Client v6.9.0 update on Apr 05, 2021
The following enhancement is available with this release dated April 05, 2021:
Enhancements
Improvements to restrict backups during Blackout Window
If you have configured the Blackout Window duration in inSync Client, inSync now ensures that backup activity is not performed on your devices during that duration.
How does this improve the end-user experience?
-
An ongoing scheduled backup or a manually triggered backup will automatically pause if the backup enters into the Blackout Window duration.
-
Backups will remain in a paused state until the Blackout Window duration is complete.
-
End-users can resume a paused backup if they wish to.
-
Administrator-triggered manual backups are initiated only when the user devices are not identified within the Blackout Window duration.
-
The user-paused backup will not resume if the paused duration ends within a Blackout Window duration.
-
Backups that are interrupted due to connectivity issues are not resumed if the device is connected to a permitted network during the Blackout Window duration.
-
inSync Client interface displays upfront messaging for the paused backups.
Adaptive inSync menu bar icon for macOS
Introducing the dynamic inSync menu bar icon for macOS Big Sur that automatically adapts the background color when switched between light mode and dark mode.
Revision Information
Product | Revision details |
---|---|
inSync Client |
Windows: r110050 macOS: r110050 Druva has not released a new version of inSync Client for Linux OS with inSync Client v6.9.0. You can continue using inSync Client v5.9 for Linux with inSync Cloud |